Troubleshooting
Troubleshooting
Table 2 Contro
l Module LED Diagnostics
Module Status LED Signal
Diagnosis
Solution
Green on
The system is powered up.
———
Yellow Internal communication is in progress.
———
Red solid
Hardware fa
ilure
Replace the module.
Red flashing fast The system is uploading software.
———
Red flashing slow
Token erro
r
Remove the
token and
upload th
e software token
again.
Table3Co
mmunication Errors
Code
Event
Type
Name Descrip
tion
Solution
CAP1
or
CAP2
Alarm
Commu-
nication
Error Air
Control
The System Logic
Controller has lost
communication
with the air
controller.
Verify Graco CAN connection on bottom of the Air
Controller.
Check status LEDs on the control module.
Cycle power.
CA00
Alarm
Com-
munica-
tion Er-
ror Logic
Con-
troller
System Logic
Controller
communication
has been lost.
Verify Graco CAN connection on the System Logic
Controller
CDP1
or
CDD
2
Alarm Duplicate
Air Con-
troller
The S
ystem Logic
Cont
roller sees
two
or more air
con
trollers set to
the
same gun.
•Thea
ir controller has the same CAN ID as another
modu
le.
•Adj
ust the selector switch on the Control Module. See
Set
Air Control Identity, page 16 for instructions.
18 3A3954B

Other manuals for Graco ProBell

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco ProBell and is the answer not in the manual?

Graco ProBell Specifications

General IconGeneral
BrandGraco
ModelProBell
CategoryController
LanguageEnglish

Related product manuals