Alarms and Warnings
82 312776K
Alarms and Warnings
NOTE: Do not use the fluid in the line that was dis-
pensed off ratio as it may not cure properly.
System Alarms
System alarms alert you of a problem and help prevent
off-ratio spraying. If an alarm occurs, operation stops
and the following occurs:
A red LED illuminates steadily or blinks on the
Booth Control.
Booth Control displays an alarm E-Code, E-1 to
E-28. See F
IG. 81.
Buzzer sounds (for E-2 only; see page 31 to set for
all alarms).
Status bar on the EasyKey Display shows the alarm
E-Code with a description (see Table 10).
System Warnings
Table 10 lists the System Warning Codes. Warnings do
not stop operation or sound an alarm. They are saved in
the date/time stamped log, which can be viewed on a
PC, using the ProMix 2KS Web Interface (see manual
313386).
To Reset Alarm and Restart
NOTE: When an alarm occurs be sure to determine the
E-Code before resetting it. See Table 10. If you forget
which E-Code occurred, use the Alarms Screens (page
26) to view the last 10 alarms, with date and time
stamps.
To reset alarms, see Table 11. Many alarms can be
cleared by simply pressing the Alarm Reset
key.
F
IG. 81. Booth Control
TI11614A
Display
Recipe Indicator (green)
Alarm Indicator (red)
Table 10: System Alarm/Warning Codes
Code Description Details
E-1 Communication Error Alarm Page 83
E-2 Potlife Alarm Page 83
E-3 Ratio High Alarm Page 84
E-4 Ratio Low Alarm Page 85
E-5 Overdose A/B Dose Too Short Alarm Page 86
E-6 Overdose B/A Dose Too Short Alarm Page 86
E-7 Dose Time A Alarm Page 87
E-8 Dose Time B Alarm Page 87
E-9 Not used NA
E-10 Remote Stop Alarm Page 88
E-11 Purge Volume Alarm Page 88
E-12 CAN Network Communication Error
Alarm
Page 89
E-13 High Flow Alarm Page 90
E-14 Low Flow Alarm Page 90
E-15 System Idle Warning Page 90
E-16 Setup Change Warning Page 90
E-17 Power On Warning Page 90
E-18 Defaults Loaded Warning Page 90
E-19 I/O Alarm Page 91
E-20 Purge Initiate Alarm Page 92
E-21 Material Fill Alarm Page 92
E-22 Tank A Low Alarm Page 92
E-23 Tank B Low Alarm Page 92
E-24 Tank S Low Alarm Page 92
E-25 Auto Dump Complete Alarm Page 93
E-26 Color/Catalyst Purge Alarm Page 93
E-27 Color/Catalyst Fill Alarm Page 93
E-28 Mix Fill Push Complete Page 93