Page #29 background imageLoading...
Page #29 background image
Pot Life Timer
310665E 29
Pot Life Timer
How Pot Life Timer Works
Pot life timer starts to countdown at the start of
Spray mode. Once the pot life timer is active, it will
continue to time down, regardless of which mode the
system is in.
When the timer reaches zero, the system closes all dis-
pense valves and a pot life (code 21) alarm occurs
(audible alarm sounds). Refer to page 33.
To Change Pot Life Time
Hold down . Turn the key to increase/decrease pot
life time (minutes).
Approximate Pot Life Volume
Use the following information to determine approximate
pot life volume (PLV) in cc:
Integrator manifold and mixer volume = 75 cc
Spray Gun Volume = 20 cc
(Hose Volume* x Feet of Hose) + 75 + 20 = PLV
Pot Life Reset Volume
The timer resets when the total spray volume exceeds
the pot life reset volume.
To change reset value, hold down . Turn the key to
increase/decrease pot life reset volume (cc).
When an Alarm Occurs
Press to clear alarm, then flush system (page 16),
or press and spray until fresh material is loaded into
system.
To Display Pot Life Time Left (in minutes)
Turn the function knob to .
Recommend setting pot life time to 1/2 of material
pot life.
Hose ID
(inches)
Volume*
(cc/foot)
3/16 5.43
1/4 9.648
3/8 21.71

Other manuals for Graco ProMix Easy

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco ProMix Easy and is the answer not in the manual?

Graco ProMix Easy Specifications

General IconGeneral
BrandGraco
ModelProMix Easy
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals