Technical Data
36 310665E
Technical Data
Mix ratio range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.1:1-10:1 (in 0.1 increments),
Ratio tolerance range . . . . . . . . . . . . . . . . . . . . . . . . . . . . up to +/- 1%
Flow rates
Minimum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.02 qt/min (0.02 lpm)*
Maximum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 gpm (3.8 lpm)
Pump size. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 cc/cycle
Pump cycle length
(one cycle = one upstroke and one downstroke) . . . . . . . 7.6 in. (193 mm)/cycle
Fluid viscosity range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50-20,000 cps (heavier viscosities can be mixed with use
of optional heaters, heated hoses, and hardware)
Fluid filtration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 mesh (238 micron) standard
Maximum fluid working pressure . . . . . . . . . . . . . . . . . . . 4700 psi (32 MPa, 324 bar)
Air supply pressure range. . . . . . . . . . . . . . . . . . . . . . . . . 60-110 psi (420-800 kPa, 4.2-8 bar)
Maximum air consumption at 100 psi (0.7 MPa, 7 bar) . .
63.0 scfm at 1 gpm (1.76 m
3
/min at 3.8 lpm)
Ambient temperature range
Operating. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32-104° F (0-40° C)
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30-160° F (–1-71° C)
External Power Supply Requirements . . . . . . . . . . . . . . . 85-250 Vac, 50/60 Hz, 2 amps maximum draw
15 amp maximum circuit breaker required
14 AWG power supply wire gauge
Heater Power Requirements . . . . . . . . . . . . . . . . . . . . . . 240 Vac Heater: 16.2 A each heater, 32.4 A total
480 Vac Heater: 8.3 A each heater, 16.6 A total
Environmental Conditions Rating . . . . . . . . . . . . . . . . . . . Indoor/outdoor
Altitude up to 4000 meters
Maximum relative humidity to 99% up to 40° C
Pollution degree (1)
Installation category (2)
Sound pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 dBA at 100 psi (0.7 MPa, 7 bar)
Wetted parts
Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See 310662
Dispense Valves . . . . . . . . . . . . . . . . . . . . . . . . . See 310655
Mix Manifold. . . . . . . . . . . . . . . . . . . . . . . . . . . . . See 310654
PC Communications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . RS-232
* Minimum flow rate is dependent on the material being sprayed and mixing capability. Test your material for spe-
cific flow rate.

Other manuals for Graco ProMix Easy

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco ProMix Easy and is the answer not in the manual?

Graco ProMix Easy Specifications

General IconGeneral
BrandGraco
ModelProMix Easy
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals