Spraying
Calibration Calibration
Calibration
Procedure Procedure
Procedure
NOTICE NOTICE
NOTICE
Topreventdamagetotheheatedhose,ahose
calibrationisrequiredifanyofthefollowing
conditionsaretrue:
Thehosehasneverbeencalibratedbefore.
Asectionofhosehasbeenreplaced.
Asectionofhosehasbeenadded.
Asectionofhosehasbeenremoved.
NOTE: NOTE:
NOTE:
TheReactorandheatedhosemustbeat
thesameambienttemperaturetogetthemost
accuratecalibration.
1.EnterSetupModeandnavigatetoSystem
screen3,thenpresstheCalibratesoftkey
.
2.PresstheContinuesoftkeyto
acknowledgetheremindertohavethehose
atambientconditions.
3.Waitwhilethesystemmeasuresthehose
resistance.
NOTE: NOTE:
NOTE:
Ifhoseheatwasonpriortothe
calibrationprocedure,thesystemwill
waituptoveminutestoallowthewire
temperaturetoequalize.
NOTE: NOTE:
NOTE:
Thehosetemperaturemustbeabove
32°F(0°C)duringcalibration.
56 333023U