Troubleshooting
Hydraulic Hydraulic
Hydraulic
Drive Drive
Drive
System System
System
Beforeperforminganytroubleshootingprocedures:
1.FollowPressureReliefProcedure,page47.
2.TurnthemainpowerswitchOFF.
3.Allowequipmenttocool.
Trytherecommendedsolutionsintheordergivenfor
eachproblem,toavoidunnecessaryrepairs.Also,
determinethatallcircuitbreakers,switches,and
controlsareproperlysetandwiringiscorrectbefore
assumingthereisaproblem.
NOTE: NOTE:
NOTE:
Motorstartupisdelayedamaximumof5
secondsfromthelasttimethemotorwasturnedoff
toreducethechanceofthemotoroverheating.
PROBLEM PROBLEM
PROBLEM
CAUSE CAUSE
CAUSE
SOLUTION SOLUTION
SOLUTION
Looseconnectionsand/orcontactor
(CT01)isnotclosing.
Checkwiringbetweenthefollowing
components:
HCMandcontactorCT01
HCMandfusesF11/F12
DamagedHCM.ReplaceHCM.
Looseconnectionsand/orcontactor
(CT01)isclosing.
Checkwiringbetweenthefollowing
components:
motorjunctionboxandCB12
CB12
contactCT01andmain
disconnectswitch(orterminal
blocksTB06andTB09)
Electricmotorwillnotstartorstops
duringoperation.
Circuitbreakertripped.ResetCB12withintheelectrical
enclosureaftercon󰘰rmingwiringis
correctanditsinsulationisintact.
36 334946H

Table of Contents

Other manuals for Graco Reactor 2 H-XP2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco Reactor 2 H-XP2 and is the answer not in the manual?

Graco Reactor 2 H-XP2 Specifications

General IconGeneral
BrandGraco
ModelReactor 2 H-XP2
CategoryPaint Sprayer
LanguageEnglish

Related product manuals