Parts
Heater Parts
17G646, 7.5kw Single Zone Heater
17G648, 10.2 kw Single Zone Heater
1
Torque to 120 ft-lbs (163 N•m).
2
Torque to 23 ft-lbs (31 N•m).
3
Apply thermal paste.
4.
Ap
ply pipe sealant and PTFE tape to all
no
n-swiveling threads and threads without
o-
rings.
5
Apply lithium grease lubricant to o-rings before
assembling in block (501).
6
Orientate sensor as shown. Insert probe until it
bottoms on heating element. Tighten ferrule on
sensor probe one turn past finger tight or 180
in-lbs (20.3 N•m).
8
Orient rupture disc housing (514) with exhaust
hole pointing away from fitting (508).
334946A 85