Pause (Heated Units)
28 311075V
Pause (Heated Units)
Refilling Tanks
Material can be added to the tanks at any time.
See page 21.
6.
Disengage piston safety lock or trigger
safety lock.
7.
Test spray onto cardboard or plastic
sheet. Verify that material fully cures in
the required length of time, and is the
correct color. Adjust pressure and tem-
perature to get desired results. Equip-
ment is ready to spray.
To bring the hose and gun back to
spray temperature after a brief break,
use the following procedure.
1.
Engage piston safety lock or trigger
safety lock.
2.
Set function knob to Slow Recirc .
ti10441a
Fusion MD2
Fusion
MD2
ti10442a
3.
Set Recirc/Spray valves to Recirc until
temperature readouts come back up.
4.
If you stop spraying for more than 2 min-
utes when using an impingement mix
gun, close gun fluid valves A and B.
Doing this will keep the internal parts of
the gun cleaner and prevent crossover.
If you are operating at high tempera-
tures or flow rates, follow instructions
under Pause (Heated Units) to bring
tanks up to temperature.
NOTICE
To prevent cross-contamination of fluids and
equipment parts, never interchange component
A (isocyanate) and component B (resin) parts or
containers.
Have at least two 5 gal. (19 liter) pails to transfer
fluid from drums to supply tanks. Label one pail
“A” and the other “B”, using the red and blue
labels provided. Always doublecheck which
material you have before pouring it in the supply
tanks. Pouring is easier if pails are not filled to
the top.
Open only one supply tank at a time, to avoid
splashing material from one tank into the other
when filling.