Flushing
311075V 31
Flushing
• Generally, flush if you will be shut down for
more than 3 days. Flush more often if
material is moisture sensitive and humidity
is high in the storage area, or if material
may separate or settle out over time.
• Flush out old fluid with new fluid, or flush
out old fluid with a compatible solvent
before introducing new fluid.
• Use the lowest possible pressure when
flushing.
• Always leave some type of fluid in system.
Do not use water.
• For long term storage, flush out the solvent
with a storage fluid such as Bayer Mesa-
moll plasticizer or, at minimum, clean motor
oil.
Flush equipment only in a well-ventilated
area. Do not spray flammable fluids. Do not
turn on heaters while flushing with flammable
solvents.
1.
Engage piston safety lock or trigger
safety lock. Close fluid valves A and B.
Leave air on.
Fusion
MD2
ti10442a
2.
Set function knob to Stop/Park .
3.
Shut off Heater Power (heated units
only). Allow system to cool.
4.
Remove recirculation tubes (31) from
supply tanks and place in original con-
tainers or waste containers.
5.
Turn Recirc/Spray valves to Recirc.
6.
Set function knob to Fast Recirc .
Pump material from supply tanks until
no more comes out.
TI7022a
31