EasyManua.ls Logo

Graco ThermoLazer 300TC - Routine Maintenance; Daily Maintenance Checks

Graco ThermoLazer 300TC
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance
36 3A1319K
Maintenance
DAILY: Check gas lines and fittings for gas leaks. Use
soap and water mixture or LP-gas leak detector to
detect gas leaks.
DAILY: Check LP-gas supply hose for abrasions, cut or
wear. Make sure hose fitting and tank fitting are free of
debris before connecting.
DAILY: Make sure kettle gas safety valve (CC) rotates
freely. Make sure valve freely moves in and out at the
“PILOT” position.
DAILY: Make sure a good spark is being produced at
the kettle pilot burner by the kettle pilot igniter electrode.
Spark gap should be 0.17 - 0.20 in. (0.43 - 0.50 cm).
DAILY: Make sure kettle main burners (A) ignite when
heat is required and shut-off when heat is not required.
DAILY: Make sure kettle pilot burner (C) is burning cor-
rectly. The flame should be 2 - 3 in. (5.0 - 7.6 cm) high
and blue/orange in color.
DAILY: Make sure LP-gas only flows to burner when
safety shut-off valve knob is pressed in.
DAILY: Make sure the screed burners are burning cor-
rectly.
DAILY: Check bead box dispenser drive wheel (27) and
tire (89) for foreign debris.
WEEKLY: Grease thermoplastic flow control gate valve
guides.
WEEKLY: Check tire pressures.
WEEKLY: Check screed box bar carbide runners for
wear.
WEEKLY: Clean the kettle to remove any debris or
burnt material.
WEEKLY (or every 3000 lb of melting): Clean ProMelt
Kettle of all overheated material.
MONTHLY: Grease agitator rod ball joint ends.
DAILY: Clean ProMelt kettle screen by scraping sides
with long-handled scraper.