4. Place suction tube in flushing fluid. Use
water for water base paint and mineral
spirits for oil-based paint. Place drain
tube in waste pail.
5. To pump, turn prime valve to down
position.
6. Turn pressure control to TurboClean
™
.
7. Trigger gun until the pump runs steady
and flushing fluid appears clear in the
waste pail.
8. Turn pressure control to OFF position.
Flush Hose and Gun
1. To flush airless hose and spray gun, turn
prime valve horizontal.
2. Hold a metal part of the spray gun
against waste pail. Disengage trigger
lock.
3. Trigger gun and turn pressure control to
TurboClean.