P a g e | 62
HT70X User manual
Version 1.0.9.4
A configuration parameter is associated with each particular field in the web configuration page.
A parameter consists of a Capital letter P and 2 to 3 (Could be extended to 4 in the future) digit numeric
numbers. i.e., P2 is associated with “Admin Password in the ADVANCED SETTINGS page. For a
detailed parameter list, please refer to the corresponding firmware release configuration template.
When a Grandstream device boots up or reboots, it will issue a request for a configuration file
“cfgxxxxxxxxxxxx”, where “xxxxxxxxxxxx” is the MAC address of the device, i.e., “cfg000b820102ab”. In
addition, device will also requests a XML configuration file “cfgxxxxxxxxxxxx.xml”. If the download of
“cfgxxxxxxxxxxxx.xml” is not successful, the provision program will issue a request for a generic
configuration file “cfg.xml”. Configuration file name should be in lower case letters.
For more details on Grandstream Device provisioning, please refer to:
http://www.grandstream.com/sites/default/files/Resources/gs-provisioning_guide_public.pdf
Firmware and Configuration File Prefix and Postfix
Firmware Prefix and Postfix allows device to download the firmware name with the matching Prefix and
Postfix. This makes it possible to store ALL of the firmwares with different version in one single directory.
Similarly, Config File Prefix and Postfix allows device to download the configuration file with the matching
Prefix and Postfix. Thus multiple configuration files for the same device can be stored in one directory.
In addition, when the field “Check New Firmware only when F/W pre/suffix changesis selected, the device
will only issue firmware upgrade request if there are changes in the firmware Prefix or Postfix.
Managing Firmware and Configuration File Download
When “Automatic Upgradeis set Yes, everythe auto check will be done in the minute specified in this
field. If set to daily at hour (0-23)”, Service Provider can use P193 (Auto Check Interval) to have the
devices do a daily check at the hour set in this field with either Firmware Server or Config Server. If set to
weekly on day (0-6)” the auto check will be done in the day specified in this field. This allows the device
periodically check if there are any new changes need to be taken on a scheduled time. By defining different
intervals in P193 for different devices, Server Provider can spread the Firmware or Configuration File
download in minutes to reduce the Firmware or Provisioning Server load at any given time.

Table of Contents

Other manuals for Grandstream Networks HT701

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grandstream Networks HT701 and is the answer not in the manual?

Grandstream Networks HT701 Specifications

General IconGeneral
BrandGrandstream Networks
ModelHT701
CategoryAdapter
LanguageEnglish

Related product manuals