Section 16: Product Fiche - HPID6R32Page 72
Product fiche concerning the Commission Delegated Regulations
(EU)No 811/2013 of 18 February 2013
(EU)No 813/2013 of 2 August 2013
16 PRODUCT FICHE
Contact Details:
Grant Engineering (Ireland) ULC, Barrack Street, Crinkle, Birr, Co. Offaly, R42 D788, Ireland.
(*) For heat pumps space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh, and
the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0.9.
Model
Outdoor unit:
Aerona
3
HPID6R32
Indoor unit:
None
Air to Water Heat Pump
Yes
Brine to Water Heat Pump
No
Low Temperature Heat Pump
No
Equipped with Supplementary Heater
No
Heat Pump Combination Heater
Yes
Parameters shall be declared for
Medium Temperature Applications (55°C)
Parameters shall be declared for
Average Climate Conditions
Item
Symbol
Value
Unit
Item
Symbol
Value
Unit
Rated Heat Output (*)
Prated
4.5
kW
Seasonal space heating
energy efficiency
ƞs
132
%
Tj = -7°C
Pdh
5.03
kW
Tj = -7°C
COPd
2.11
-
Degradation co-efficient (**)
Cdh
0.99
-
Tj = +2°C
Pdh
3.21
kW
Tj = +2°C
COPd
4.03
-
Degradation co-efficient (**)
Cdh
0.99
-
Tj = +7°C
Pdh
2.20
kW
Tj = +7°C
COPd
5.10
-
Degradation co-efficient (**)
Cdh
0.98
-
Tj = +12°C
Pdh
1.78
kW
Tj = +12°C
COPd
6.15
-
Degradation co-efficient (**)
Cdh
0.99
-
Tj = bivalent temperature
Pdh
4.50
kW
Tj = bivalent temperature
COPd
1.90
-
Tj = operation limit
temperature
Pdh
4.50
kW
Tj = operation limit temperature
COPd
1.90
-
Tj = -15°C (if TOL < -20°C)
Pdh
-
kW
Tj = -15°C (if TOL < -20°C)
COPd
-
Bivalent temperature
Tbiv
-10
°C
Operation limit temperature
TOL
-10
°C
Heating water operating limit
temperature
WTOL
60
°C
Power consumption in modes other than active mode
Supplementary Heater
Off Mode
P
OFF
0.10
kW
Rate heat output
P
sup
0
kW
Thermostat-off mode
P
TO
0.04
kW
Standby mode
P
SB
0.10
kW
Type of energy input
Crankcase heater mode
P
CK
0.00
kW
Other items
Capacity control
Variable
Rated airflow rate, outdoors
-
2082
m³/h
Sound power level
indoors/outdoors
L
WA
44/65
dBA
Annual Energy consumption
Q
HE
2755
kWh
For heat pump combination heater
Water heating energy efficiency
ƞwh
114
%
Declared load profile
L
Reference Hot Water Temperature
θ’
WH
49.04
°C
Daily electricity consumption
Qelec
4.23
kWh
Actual Volume of cylinder under test
206.8
Litres
Annual electricity consumption
AEC
897.77
kWh/a
Standby Cylinder Heat Loss
1.76
kWh

Table of Contents