Page #77 background imageLoading...
Page #77 background image
Section 16: Product Fiche - HPID13R32 Page 77
Contact Details:
Grant Engineering (Ireland) ULC, Barrack Street, Crinkle, Birr, Co. Offaly, R42
D788, Ireland.
(*) For heat pumps space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh, and
the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0.9.
Model
Outdoor unit:
Aerona
3
HPID13R32
Indoor unit:
None
Air to Water Heat Pump
Yes
Brine to Water Heat Pump
No
Low Temperature Heat Pump
No
Equipped with Supplementary Heater
No
Heat Pump Combination Heater
Yes
Parameters shall be declared for
Low Temperature Applications (35°C)
Parameters shall be declared for
Average Climate Conditions
Item
Symbol
Value
Unit
Item
Symbol
Value
Unit
Rated Heat Output (*)
Prated
10.0
kW
Seasonal space heating
energy efficiency
ƞs
216
%
Declared capacity for heating for part load at indoor Declared coefficient of performance or primary energy ratio for
Temperature 20°C and outdoor temperature Tj part load at indoor temperature 20°C and outdoor temperature Tj
Tj = -10°C
Pdh
10.0
kW
Tj = -10°C
COPd
2.90
-
Degradation co-efficient (**)
Cdh
0.99
-
Tj = -7°C
Pdh
9.60
kW
Tj = -7°C
COPd
3.03
-
Degradation co-efficient (**)
Cdh
0.99
-
Tj = +2°C
Pdh
6.10
kW
Tj = +2°C
COPd
6.20
-
Degradation co-efficient (**)
Cdh
0.99
-
Tj = +7°C
Pdh
4.30
kW
Tj = +7°C
COPd
8.50
-
Degradation co-efficient (**)
Cdh
0.98
-
Tj = +12°C
Pdh
4.10
kW
Tj = +12°C
COPd
10.30
-
Degradation co-efficient (**)
Cdh
0.99
-
Tj = bivalent temperature
Pdh
10.0
kW
Tj = bivalent temperature
COPd
2.90
-
Tj = operation limit
temperature
Pdh 10.0 kW Tj = operation limit temperature COPd
2.90
-
Tj = -15°C (if TOL < -20°C)
Pdh
-
kW
Tj = -15°C (if TOL < -20°C)
COPd
-
Bivalent temperature
Tbiv
-10
°C
Operation limit temperature
TOL
-10
°C
Heating water operating limit
temperature
WTOL
60 °C
Power consumption in modes other than active mode
Supplementary Heater
Off Mode
P
OFF
0.10
kW
Rate heat output
P
sup
0.00
kW
Thermostat-off mode
P
TO
0.04
kW
Standby mode
P
SB
0.10
kW
Type of energy input
Crankcase heater mode
P
CK
0.00
kW
Other items
Capacity control
Variable
Rated airflow rate, outdoors
-
4464
m³/h
Sound power level
indoors/outdoors
L
WA
39/61
dBA
Annual Energy consumption
Q
HE
3439
kWh
For heat pump combination heater
Water heating energy efficiency
ƞ
wh
%
Declared load profile
NA
Daily electricity consumption
Qelec
kW/h
Annual electricity consumption
AEC
kW/h
Product fiche concerning the Commission Delegated Regulations
(EU)No 811/2013 of 18 February 2013
(EU)No 813/2013 of 2 August 2013