3−25
CHAPTER 3 Settings and Measurement
(2)-2 Captured data file name
Select the name of a file or folder to which you want to save capture data.
<If the naming method is Auto> <If the naming method is Arbitrary>
Setting Description
(1) Folder Specify a folder to which you want to capture (or save) data. Refer to page 3-44,
"File box" for details.
(2) File Specify a file to which you want to capture (or save) data. Refer to page 3-44, "File
box" for details.
(3) Name Type Set how a data file should be named.
Auto :
Automatically supplies the file name.
Example: 20050101-123456_UG.GBD
Number part : File creation date
* The file is created on January 1, 2005,
12:34:56 in this example.
UG : User number of the user capturing data
UG: Guest
U1: User 1
U2: User 2
GBD : Data format GBD
(Binary data)
CSV (Text format)
Arbitrary : Data is captured to a file with an entered file name.
Sequentialnumber
: A file is created with an arbitrary file name that has been en-
tered,followedbyasequentialnumber.
Example: If the file name is "TEST"
First time : TEST_SER1.GBD
Second time : TEST_SER2.GBD
Third time : TEST_SER3.GBD
* If the same file name already exists, _CP* is added to the end of a file name to
prevent overwriting. The asterisk (*) represents a number.
Example: TEST_CP1.GBD
(4) File Type Sets the file format used to save data.
GBD : Creating a data file in Graphtec's proprietary binary format
* Data tampering can be prevented.
CSV : Creating a data file in text format
* Replaying on the GL820 is not available.
When you save files, create a folder and then save the files in the folder. Regardless of the remaining
capacity, if you try to save files in the root directory, you may not be able to save files due to file system
restrictions.
Changing the sampling interval, capture destination, number of measuring channels (number of channels
for which the input is not Off), etc. will change the Capture Space and Capture Time on the screen.
If you find that the measurement time exceeds the Capture Time, take one of the following measures:
• Changethesamplinginterval.
• CopythelesontheinternalmemorytoyourPCanddeletethem.
• ChangethecapturedestinationtoUSBmemorywithlargerfreespace.
Capture Space : Displays the amount of memory space available for capture at the capture destination.
Capture Time : Displays time available for capture.
* The Capture Time is calculated for 2 GB at the maximum.
The Capture Time more than 366 days is displayed as More Than 366 days.