130
Detail program description - Control adjust
Using the arrow key on the left or right touch pad,
move the marker frame over the "ph. Tim." column – and
"Motor" column, if applicable – to the right.
Pha1
Pha2
Pha3
Name Sw.time
Pha4
Pha5
+
+
Normal
Launch
Dist.
–
–
0.1s
0.1s
0.1s
0.1s
0.1s
Briefl y tap the center SET key on the right touch pad to
highlight the value fi eld. You can then select switch times
between 0 and 9.9 s in this fi eld.
Example:
Pha1
Pha2
Pha3
Name
Pha4
Pha5
+
+
–
–
3.0s
2.0s
4.0s
0.1s
0.1s
Sw.time
Normal
Launch
Dist.
The switch time is set to 4.0 s when switching from any
phase to Phase 1 "Normal".
When switching from e. g. Phase 1 to Phase 3, the
switch time is set to 2.0 s and to 3.0 s when switching
from Phase 1 or 3 to Phase 2 "Launch".
Such asymmetric transition times can be useful when
(e. g.) switching between highly contrasting fl ight phases,
such as e. g. between aerobatics and normal fl ight.
Tapping the or keys on the right touch pad at
the same time (CLEAR) will reset the time to 0.1 in the
active value fi eld.
Note:
The "switch time" set here applies uniformly to all
settings that are specifi c to fl ight phases, and thus to
all mixers activated in the "Wing mixers" menu (see
page 146). Accordingly, the transition between fl ight
phase-specifi c mixers does not occur abruptly. If you
want individual servos to be switched without a delay,
however, defi ne these accordingly in the "Non-delayed
channels" menu (see page 137).