EasyManua.ls Logo

Gree GMV-PD160W/NAB-M

Gree GMV-PD160W/NAB-M
133 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
33
DC Inverter Multi
VRF Service Manual
DPOUSPM
Serial No. Description
1 Wall
2 Power Supply Box (86)
3 Bottom Base(including power supply module board)
4 Screw
5 Top Cover(including the display board)
After the installation, it is necessary to make the debugging to guarantee the normal communication.
6.5.2 Debugging and Viewing the Port No. and the Indoor Unit Address
Debugging setting: In the event that the unit is initially powered on, the setting for the project changes,
or the serial port is replaced, and then it is available to go to the debugging status by pressing “Mode” and
³7KX´VLPXOWDQHRXVO\IRU¿YHVHFRQGVXQGHUZKLFKSDJHLWLVHQDEOHGWRFKHFNDXWRPDWLFDOO\DQGGLVWULEXWH
WKHDGGUHVVRIWKHLQGRRUXQLWPLQXWHVODWHUWKHGHEXJJLQJLV¿QLVKHGDQGWKHLQGRRUXQLWZKLFKJDLQVWKH
address is under control and the unaddressed indoor unit is not.
Viewing the serial port and the indoor unit address: It is available to go to the debugging page by pressing
³0RGH´DQG³7KX´VLPXOWDQHRXVO\IRU¿YHVHFRQGVXQGHUZKLFKSDJHLWLVHQDEOHGWRYLHZWKHVHULDOSRUWDQG
address of the corresponding indoor unit
The press on “Confirm/Cancel” can confirm this debugging setting and go to the viewing state of the
current indoor unit; otherwise this setting will not be saved.
See Fig.6.5.7 for the debugging operation. Fig.6.5.7 shows the indoor unit 1 and indoor unit 2, both of
which are connected with the port COM2. The address of one is 01 and the other is 04.
Press Mode and Thu
simultaneously for five seconds
to go to the debugging page.
Press the code button of the indoor unit
to inquire about its corresponding serial
port and address.
Press Confirm/Cancel”to makea
confirmation.
Fig.6.5.7 Debugging
6.5.3 Labeling
A label is provided to identify the relationship of the indoor unit No. and the corresponding room name. The
user can write down the indoor unit No. and its corresponding room name on the label which then will be stuck
to the inside of the cover of the smart zone controller so that the user can be clear about the control object.
For instance, when the user has installed the air conditioners in the child room, bedroom and living
room, after the debugging it is available to view the indoor unit No. of each room and get clear about their
corresponding relationship.
Room Name Child Room Bedroom Living Room
Indoor Unit Address Port 1,Indoor Unit 04 Port 1, Indoor Unit 05 Port 1,Indoor Unit 06
Indoor Unit No. 1 2 3
After get clear about the relationship of the indoor unit no. and the room, the user can write “Child Room”,
“Bedroom”, “Living Room” on the place “1”, “2” and “3” respectively on the label and then stick the label to the
inner side of the smart zone controller.
See 6.5.8 for the label.

Table of Contents

Other manuals for Gree GMV-PD160W/NAB-M

Related product manuals