38
W450311 Rev C 2/13
7.2 WAD/ISS Troubleshooting Table
Error Message / Problem
Cause
Correction
“SWING SENSOR SIGNAL 1
ERROR!”
“SWING SENSOR SIGNAL 2
ERROR!”
“SWING SENSOR ERROR!”
“SWING SENSOR LOGIC
REPORT!
Cable from sensor to condition box
disconnected.
Cable from sensor to conditiong box
grounded.
Replace sensor.
“SWING SENSOR COMMS
ERROR!”
Cable from conditioning box to
computer disconnected at computer or
conditiong box.
Cable from condition box to computer
grounded.
Check cable.
Check connection at
conditioning box and
computer.
Replace cable.
If display shows load, angle,
radius, etc, replace the
conditioning box.
Intermittent, inaccurate, or no output
activity
WAD/ISS too far from target within
swing drive.
WAD/ISS sensor too close to target
within swing drive.
WAD/ISS not responding normally but
drawing normal current and providing
normal outputs.
WAD/ISS disconnected from computer.
Check sensor and sensor
connection.

Other manuals for GREER Company Insight

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GREER Company Insight and is the answer not in the manual?

GREER Company Insight Specifications

General IconGeneral
BrandGREER Company
ModelInsight
CategoryControl Panel
LanguageEnglish