Model 613-VS2-LES, Log End Slicer Sanitation
R-1176866 613-VS2-LES_CJL20160114.doc:1/15/2016 4:21 PM Grote Company 38
15. The HMI screen should be gently wiped with soap and water and sanitizer. Gently rinse off all
chemicals. Do not use high pressure water on the HMI screen. Shut the cover to the Electrical
Control Enclosure.
16. The four latching switches should likewise be hand sanitized and gently rinsed. Once this is
done, some customers cover these switches to prevent more aggressive water sprays from
penetrating these devises. The four latching switches are located at:
a. The carryout conveyor
b. The entrance guard to the 613
c. The latching spool connecting the autoloader to the 613-VS2
d. The tunnel guard
17. Pre-soak machine if this step is part of your cleaning operation. The pre-soak may include
chemicals, but is normally a hot potable water rinse to loosen dried product clinging to the
machine.
18. Spray entire machine with hot potable water rinse starting at the top and working down. Pay
particular attention to the product zone to assure the removal of all excess product.
NOTE: The Grote Company supplies a scraper tool to clean the Blade Guide slot.
Use this tool with cleaner and sanitizer to thoroughly clean the Blade Guide slot.
CAUTION: Before wash down, verify Operator Interface covers and plug covers are in
place and all electrical enclosures are latched. Maintain a proper spray nozzle distance
from the equipment. FAILURE TO DO SO MAY DAMAGE THE EQUIPMENT.
Be careful in using high-pressure spray on certain system areas. Keep high-
pressure spray at least 12 inches away from the following areas:
AC motors: Shaft seals, flange and electrical connections.
Guard Switches and Sensors: Electrical connection and penetration areas.
Gearboxes: Shaft seal areas and flange connections.
Electrical enclosures: Door seals, and electrical connection and penetration areas.
Electrical Control Buttons and Switches: Electrical connection and penetration
areas.
Electrical Connections: Electrical connection and penetration areas.
Operator Interface: Door seals, OI buttons, and electrical connection and
penetration areas. Place protective bag over OI during high-pressure wash-down.
NOT