1174605.doc
Inverter Parameters
Mitsubishi D-700
Part No. : 1174605
Machine : 613-VS2 BLADE
Inverter : 2 hp, 230 v, 1127982
Date : 4/21/14
Engineer : MAK
Parameter
No.
Parameter Units Range Res Factory Machine
0 Torque Boost (manual) % 0 to 30 0.1 6 6
1 Upper limit frequency Hz 0 to 120 0.01 120 60 *
2 Lower limit frequency Hz 0 to 60 0.01 0 20 *
3 Base frequency Hz 0 to 400 0.01 60 60
4 Multi-speed setting (high speed) Hz 0 to 400 0.01 60 60
5 Multi-speed setting (middle speed) Hz 0 to 400 0.01 30 30
6 Multi-speed setting (low speed) Hz 0 to 400 0.01 10 10
7 Acceleration Time Sec 0 to 3600 0.1 5 1.5 *
8 Deceleration Time Sec 0 to 3600 0.1 5 1.5 *
9 Electronic thermal relay A 0 to 15 0.1 4.1 3.4 *
73 0-5V/0-10V Selection 0 to 1 1 1 1
79 Operation mode 1-4,6,7 1 0 3 *
125 Terminal 2 frequency setting gain
frequency
Hz 0 to 400 0.01 60 60
126 Terminal 4 frequency setting gain
frequency
Hz 0 to 400 0.01 60 60
160 Extended function display selection 0,9999 1 0 0
192 A, B, C, Terminal Function
Selection
0 to 9999 1 99 11 *
C2 Terminal 2 frequency setting bias
frequency
Hz 0 to 400 0.01 0 0
Clr Parameter clear 0, 1, 2 0 0
* denotes machine settings different from factory settings
Set frequency to 60.0 Hz