SPF5000TL HVM modelsuggest connect with 3 pcs in series4 parallel330W
panel.
2. Check battery specificationwhether it’s suitable for inverter model or not.
3. Ask battery supplier for help.
3.15 warning 35
Fault description:Cell under voltage.
Analysis
1. Battery cell voltage is low.
Suggestions:
1. Test battery cell real voltagecheck load capacity if it’s really lowdisconnect some
load.
2. If connect with some special loadlike water pumpits rate power should be below
1.5kwconnect with SPF5000TL HVM modelbecause normally it needs 3 times of
rate power when it startup.
3.16 warning 36
Fault description:Total over voltage.
Analysis
1. Battery voltage is high.
Suggestions:
1. Test battery real voltagecheck pv panels configuration if it’s really highfor
SPF5000TL HVM modelsuggest connect with 3 pcs in series4 parallel330W
panel.
2. Check battery specificationwhether it’s suitable for inverter model or not.
3. Ask battery supplier for help.
3.17 warning 37
Fault description:Total under voltage.
Analysis
1. Battery voltage is low.
Suggestions:
1. Test battery real voltagecheck load capacity if it’s really lowdisconnect some load.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt SPF3000TL HVM and is the answer not in the manual?

Growatt SPF3000TL HVM Specifications

General IconGeneral
Rated Power3000W
Input Voltage230V AC
Output Voltage230V AC
Efficiency93%
Dimensions330 x 485 x 135 mm
Weight12 kg
Max. PV Array Power4000W
Max. Charging Current60A
Max. AC Charging Current30A
Max. Solar Charging Current60A
Number of MPP Trackers1
Output Frequency50/60Hz
CommunicationRS232

Related product manuals