3.21 warning 41
Fault description:Charge over temperature.
Analysis:
1. Battery charging current is over battery accepted charging current.
Suggestions:
1. check pv panels configuration if it’s really high,for SPF5000TL HVM model,suggest
connect with 3 pcs in series,4 parallel(330W panel).
2. Check battery specification,whether it’s suitable for inverter model or not.
3. Ask battery supplier for help.
3.22 warning 43
Fault description:Battery over temperature.
Analysis:
1. Battery charging current is over battery accepted charging current.
Suggestions:
1. check pv panels configuration if it’s really high,for SPF5000TL HVM model,suggest
connect with 3 pcs in series,4 parallel(330W panel).
2. Check battery specification,whether it’s suitable for inverter model or not.
3. Ask battery supplier for help.
3.23 warning 44
Fault description:Battery under temperature.
Analysis:
1. Battery temperature is low.
Suggestions:
1. Check battery specification,whether it’s suitable to work on this site or not.
2. Ask battery supplier for help.
3.24 warning 45
Fault description:System shut down.
Analysis: