EasyManuals Logo

Growatt SPF3000TL HVM User Manual

Growatt SPF3000TL HVM
22 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
13
3.21 warning 41
Fault description:Charge over temperature.
Analysis
1. Battery charging current is over battery accepted charging current.
Suggestions:
1. check pv panels configuration if it’s really highfor SPF5000TL HVM modelsuggest
connect with 3 pcs in series4 parallel330W panel.
2. Check battery specificationwhether it’s suitable for inverter model or not.
3. Ask battery supplier for help.
3.22 warning 43
Fault description:Battery over temperature.
Analysis
1. Battery charging current is over battery accepted charging current.
Suggestions:
1. check pv panels configuration if it’s really highfor SPF5000TL HVM modelsuggest
connect with 3 pcs in series4 parallel330W panel.
2. Check battery specificationwhether it’s suitable for inverter model or not.
3. Ask battery supplier for help.
3.23 warning 44
Fault description:Battery under temperature.
Analysis
1. Battery temperature is low.
Suggestions:
1. Check battery specificationwhether it’s suitable to work on this site or not.
2. Ask battery supplier for help.
3.24 warning 45
Fault description:System shut down.
Analysis

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt SPF3000TL HVM and is the answer not in the manual?

Growatt SPF3000TL HVM Specifications

General IconGeneral
Rated Power3000W
Input Voltage230V AC
Output Voltage230V AC
Efficiency93%
Dimensions330 x 485 x 135 mm
Weight12 kg
Max. PV Array Power4000W
Max. Charging Current60A
Max. AC Charging Current30A
Max. Solar Charging Current60A
Number of MPP Trackers1
Output Frequency50/60Hz
CommunicationRS232