Maximum output
fault peak current
65A(56uS)
Maximum output
over current
protection
65A
Phase factor at
rate power
1
Displacement
power factor,
configurable*
0.8leading…
0.8lagging
0.8leading…
0.8lagging
0.8leading…
0.8lagging
0.8leading…
0.8lagging
0.8leading…
0.8lagging
0.8leading…0.
8lagging
THDI <3% <3% <3% <3% <3% <3%
AC connection Single phase
Single phase
Single phase
Single phase
Single phase
Single phase
EPS output data(AC power)
Growatt SPH
&SPH TL BL-
Rated output
apparent power
3000VA&30
00VA
3000VA&368
0VA
3000VA&400
0VA
3000VA&400
0VA
3000VA&400
0VA
3000VA&4000
VA
Nominal voltage
230V 230V 230V 230V 230V 230V
AC output
50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz
Growatt SPH
&SPH TL BL-UP
Rated output
current
13A/13A 13A/16A
13A/17.5A
13A/17.5 13A/17.5A
13A/17.5A
THDv 3% 3% 3% 3% 3% 3%
Switch time
TL BL-UP))
≤10ms ≤10ms ≤10ms ≤10ms ≤10ms ≤10ms
BAT data(DC)
Battery voltage
range
42~59V 42~59V 42~59V 42~59V 42~59V 42~59V
Minimum full
load voltage
46V 48V 48V 48V 48V 48V
Growatt
SPH&SPH TL
BL-UP Rated
charging and
discharging
current
66A& 66A
66A&75A 66A&85A 66A&85A 66A&85A 66A&85A
Growatt
SPH&SPH TL
BL-UP
Continuous
charging /
3000W&300
0W
3000W&368
0 W
*1
3000W&400
0 W
*1
3000W&400
0 W
*1
3000W&400
0
W
*1
3000W&4000
W
*1