Always operate the pump in accordance with
established routines and check the equipment and
accessories regularly. Make sure the pump and
equipment settings cannot be changed by
unauthorised persons.
Related information
2.1 Product description
8.3 Oil check and change
7. Handling and storing the product
DANGER
Crushing hazard
Death or serious personal injury
‐ Move the pump only by a forklift or a
lifting crane.
‐ Before lifting the pump, make sure the
centre of gravity is between the forklift
arms.
7.1 Storing the product
Leave the cable end protectors and sensor
cables on the power supply until making
the electrical connection. Make sure the
free cable ends are not exposed to mois-
ture or water as it may cause damage to
the motor.
During long periods of storage, protect the pump
against moisture and heat.
If the pump is stored for long periods, turn
the impeller by hand at least bi-monthly to
prevent the seal faces of the lower me-
chanical shaft seal from seizing up.
If the impeller cannot be turned by hand,
contact an authorised service workshop.
For dry-installed pumps, make sure the
cooling jacket is empty before storing the
product.
After a long period of storage, inspect the pump
before putting it into operation. Make sure the
impeller can rotate freely.
Pay attention to the condition of the shaft seals, O-
rings and cable entries.
32