15.6 The pump performance is insufficient
Grundfos Eye
Indicator
light
Automatic
reset
Cause Remedy
- - Pump inlet pressure is too low. Check pump inlet conditions.
- - Pump is undersized.
Replace the pump with a
larger pump.
- -
Inlet pipe, inlet strainer or
pump are partially blocked by
impurities.
Clean the inlet pipe or the
pump.
- - Leakage in the inlet pipe. Repair the inlet pipe.
- -
Air in the inlet pipe or the
pump.
Prime the inlet pipe and the
pump. Check pump inlet
conditions.
15.7 The pump starts and stops too
frequently
Grundfos Eye
Indicator
light
Automatic
reset
Cause Remedy
- -
Leakage in suction pipe or
air in the water.
Restore the water supply or
repair suction pipe.
- -
A tap has not been closed
entirely after use.
Check that all taps have been
closed. See section Anti-
cycling.
- -
Minor leakage in the
system.
Check the system for leakages.
See section Anti-cycling.
31
English (GB)

Table of Contents

Other manuals for Grundfos SCALA1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grundfos SCALA1 and is the answer not in the manual?

Grundfos SCALA1 Specifications

General IconGeneral
Inlet/Outlet Size1 inch
Weight10 kg
Mains Frequency50/60 Hz
Pumped liquidClean water
Housing MaterialComposite
Pump TypeSelf-priming, multistage centrifugal pump
Power Supply1 x 230 V
Liquid Temperature Range0°C to 45°C
Protection ClassIPX4D
System PressureMax. 10 bar
ApprovalsCE, EAC
Installation TypeHorizontal

Related product manuals