PX Control Panel User Manual – Issue C
- 33 -
Event log only messages
Log Text Additional Data Display Text Event Description
230v Fault NONE (see note) NONE Mains supply failed
230v OK NONE (see note) NONE Mains supply restored
Active Circuit Circuit nnn Cctnnn User selected active circuit test
Alarm (master shunt) Circuit nnn Cctnnn Master shunt type circuit alarms
Alarm Abort User nn, Keypad m Usnn, KPm Alarm abort signal transmitted.
Auto Check Fail Circuit nnn Cctnnn A Circuit has failed to activate
during the auto check period.
Auto Check OK NONE NONE Circuit Auto Check was OK
Bypass User nn, Circuit mmm Usnn Cctmmm Circuit bypassed
Cannot set User nn, Area m Usnn, Am User was not able to set an area
Cct Tested Circuit nnn Cctnnn Circuit responded in walk test
Changed Code User nn, Keypad m Usnn, KPm User changes own code
Changed Code User nn, User mm Usnn, Usmm Manager or GSR user changes
code for another user
Changed Time User nn, Keypad m Usnn, KPm Time modified, old time and new
time are logged
Check Fuse n N Panel fuse number
Check Fuse Conc n Conc n Concentrator fuse
Check Fuse OPM n OPM n Output module fuse
Check Fuse Door n Door n Access module fuse
Clear Circuit nnn Cctnnn Master shunt type circuit clears
Code Clash User nn, User mm Usnn, Usmm User has chosen a new code
which is the same as another
user
Comm Acknowledge n N Central station acknowledge
alarm report
Comm Fail n N Central station fails to
acknowledges alarm report
Comm Test User nn, Keypad m Usnn, KPm User or the panel tested the
communicator(s)
Duress Alarm User nn, Keypad m Usnn, KPm User enters a duress code
Engineer Reset Circuit nnn Cctnnn Engineer reset type circuit
alarms
Entry Started Circuit nnn Cctnnn Entry circuit opens
Failed Auto Set User nn, Area m Usnn, Am Event programmer failed to auto
set due to circuits in alarm
Fault Circuit nnn Cctnnn A Circuit short circuit when unset
or in alarm when trying to set
Fault Keypad n KPn Failed poll when unset
Fault Conc nn Conc nn Failed poll when unset
Fault OPM nn OPM nn Failed poll when unset
Fault SM n SM n Failed poll when unset
Fault Door nn Door nn Failed poll when unset
First code User nn, Keypad m Usnn, KPm User entered code on Dual code
keypad
Head Count Number Number of activations of all
circuits programmed with the
head count option while the panel
was unset.
Isolate User nn, Circuit mmm Usnn Cctmmm Circuit isolated by user
Isolate User nn, Concm Usnn, m Concentrator isolated by user
Key Set Req. Circuit nnn Cctnnn Key type circuit alarms
Key Unset Req. Circuit nnn Cctnnn Key type circuit clears
Intelligent Security & Fire Ltd