PX Control Panel User Manual – Issue C
- 34 -
Event log only messages
Log Text Additional Data Display Text Event Description
Knock Circuit nnn Cctnnn Circuit first knock
Line Block NONE NONE SmartDial has reported a line
blocked condition
Line Fault
1 - 50 volts not present
2 - Line block test failure
3 - No acknowledge from
central station
4 - Main PCB LF input
5- SmartDial Fault
NONE Communicator has reported a
line fault
Lockout Keypad n KPn Incorrect code attempt limit
reached on the keypad
Logged Off User nn, Keypad m Usnn, KPm User logged off keypad
Logged On User nn, Keypad m Usnn, KPm User logged on keypad
Managed Rst Keypad m KPm Managed reset code entered
Marginal Circuit nnn Cctnnn A Circuit is marginal
Mult. Alarm Circuit nnn Cctnnn Circuit has alarmed up to the
multiple alarm limit
Normal User nn, Concm Usnn, m Isolate removed from a
concentrator
Normal User nn, Circuit mmm Usnn Cctmmm Bypass or isolate removed from a
circuit
PC Access User 00 Usnn A GSR user has logged on
remotely.
Power Fail NONE (see note) NONE Supply voltage has
fallen to the power fail threshold
Pre-Warning Circuit nnn Cctnnn A circuit has been alarmed during
the entry period
Reprogrammed User nn, Keypad m Usnn, KPm A configuration option(s) has
been changed
Reset Circuit nnn Cctnnn An area has been reset
Reset User nn, Area m Usnn, Usnn An area has been reset
Clear Circuit nnn Cctnnn A Circuit alarm has cleared.
Restored Code(s) User nn, Keypad m Usnn, KPm All codes have been restored to
default
Set User nn, Area m Usnn Am Area has been set by a user
Shunt Off Circuit nnn Cctnnn A master shunt circuit or the
event programmer schedule has
removed the shunt from a circuit
Shunt On Circuit nnn Cctnnn A master shunt circuit or the
event programmer schedule has
shunted a circuit
Soak Alarm Circuit nnn Cctnnn A circuit on soak test has
alarmed
Soak Failed Circuit nnn Cctnnn At the end of the soak period any
circuit which has alarmed is
logged as failed
Soak Off Circuit nnn Cctnnn A circuit has been taken off soak
Soak On Circuit nnn Cctnnn A circuit has been put on soak
Software Error N N A software error has been logged
Temp Bypass Circuit nnn Cctnnn A circuit has been temporarily
(until clear) bypassed
TX On N N TX channel N on
TX Off N N TX channel N off
Unset User nn, Area m Usnn Am A user has unset the area