7
Item Requirements Result
humidity { RT-MSR810
{ RT-MSR810-W
{ RT-MSR810-W-DB
{ RT-MSR810-LM
{ RT-MSR810-LM-CNDE-SJK
{ RT-MSR810-W-LM
{ RT-MSR810-10-PoE
{ RT-MSR810-LM-HK
{ RT-MSR810-W-LM-HK
{ RT-MSR810-LM-GL
{ RT-MSR810-W-LM-GL
• 0% to 95% (noncondensing):
{ RT-MSR810-LME
{ RT-MSR810-LMS
{ RT-MSR810-LMS-EA
{ RT-MSR810-LUS:
Cleanness
Dust concentration ≤ 3 × 10
4
particles/m
3
(no visible dust
on the tabletop over three days)
ESD prevention
• The router and floor are reliably grounded.
• The equipment room is dust-controlled.
• Humidity and temperature are maintained at
acceptable levels.
• An ESD wrist strap is available.
EMI prevention
• A single-phase three-wire power receptacle with
protection earth (PE) is available for filtering
interference from the power grid.
• The router is far away from radio transmitting
stations, radar stations, and high-frequency devices.
• Electromagnetic shielding, for example, shielded
interface cables, is used as required.
Lightning
protection
• The router is reliably grounded.
• The power receptacle is reliably grounded.
• (Optional.) Port lightning protectors are available. A
signal lightning arrester is required at the input end of
an external signal cable.
• (Optional.) Power lightning protectors are available.
Electricity safety
• A UPS is available.
• The external power switch is located so to shut off
the power immediately when an accident occurs.
Workbench
• The workbench is stable.
• The workbench is reliably grounded.
Safety
precautions
• The router is far away from any sources of heat or moisture.
• The emergency power switch in the equipment room is identified and
accessible.
Tools
• Installation accessories supplied with the router are ready.
• User-supplied tools are ready.
Reference
• Documents shipped with the router are available.
• Online documents are available.