9
Operating mode
Description
system.
HBA
RAID functions are disabled. Raw physical drives are exposed to the system.
Before setting this mode, you must delete all RAID arrays and hot spare
drives, and perform the Uninitializing drives operation for all drives.
Auto Volume
In this mode, raw physical drives with system partitions are exposed to the
system, and physical drives without system partitions are configured as
simple volumes. Before setting this mode, you must delete all RAID arrays
and hot spare drives in the system.
Simple Volume
In this mode, only non-redundant RAID arrays with the simple volume level
(each contains only one drive) can be created. RAID arrays with other RAID
levels cannot be created. Before setting this mode, you must delete all RAID
arrays and hot spare drives in the system.
Scanning drives
The storage controller might fail to timely recognize drives after the drives are hot swapped. To
solve this problem, you can scan drives.
To scan drives:
1. On the storage controller configuration screen as shown in Figure 10, select Logical Device
Configuration, and press Enter.
Figure 10 Storage controller configuration screen
2. On the screen as shown in Figure 11, select Rescan Drives, and press Enter to scan drives.

Other manuals for H3C UniServer R4900 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C UniServer R4900 G3 and is the answer not in the manual?

H3C UniServer R4900 G3 Specifications

General IconGeneral
BrandH3C
ModelUniServer R4900 G3
CategoryServer
LanguageEnglish

Related product manuals