9. ERROR MESSAGES
System Error
When the power is turned on, the system
automatically checks its memory and the stored
program. If a problem is found, all the heat
range indicator lamps will light and the tip will
not heat.
NOTE:
Sensor error also occurs if the tip is not inserted
properly.
Sensor Error
When there is the possibility that a failure has
occurred in the sensor or heater (including the
sensor circuit), the heat range indicator lamp
will blink rapidly and the heater is shut down.
NOTE:
Only the FM-2021 is compatible with the FP-101.
Heater terminal short circuit
error
Soldering iron error
7.5
6.5
8.07.0
All the heat range indicator lamps will blink, and
the alarm will sound continuously. Possible
causes are: the tip is inserted the wrong way, an
incompatible tip is inserted, or a foreign object
is in the connector.
The yellow and red heat range indicator lamps
will blink if the connector cord is not attached to
the station OR the wrong soldering iron is
connected.