Hanna Instruments HI991003 User Manual

Hanna Instruments HI991003
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
HI991003
Extended Range Waterproof
pH, ORP, and Temperature
Meter
INSTRUCTION MANUAL
Impex Produkter
Question and Answer IconNeed help?

Do you have a question about the Hanna Instruments HI991003 and is the answer not in the manual?

Hanna Instruments HI991003 Specifications

General IconGeneral
ModelHI991003
CategoryMeasuring Instruments
pH Range-2.00 to 16.00 pH
pH Resolution0.01 pH
pH Accuracy±0.02 pH
Temperature CompensationAutomatic
Number of Batteries4
IP RatingIP67
DisplayLCD
TypepH/Temperature
Temperature Resolution0.1°C
Temperature Accuracy±0.5°C
CalibrationAutomatic, up to 3 points
pH Calibration Buffers4.01, 7.01, 10.01
Battery Type1.5V AAA
Battery LifeApproximately 1000 hours
Auto-off8 minutes
Environment0 to 50 °C, 100% RH

Summary

Preliminary Examination

General Description and Intended Use

Main Features

Specifications

Display Description

Operational Guide

Connect the Electrode

Instructions on how to properly connect the probe to the meter.

Turn the Meter On

Procedure for powering the meter on and initial startup sequence.

Select Measurement Range

How to choose between pH and pH-mV measurement modes.

Freeze Measurement Values

Method to hold and display static readings on the LCD.

Enter Calibration Mode

Steps to access the calibration function for accurate readings.

Enter Setup Mode

Process to access settings for temperature unit, auto-off, and beep.

Turn the Meter Off

How to properly shut down the meter.

pH Measurement & Calibration

Instructions for performing pH measurements and initial calibration.

pH Calibration

Detailed guide for calibrating the pH sensor using buffer solutions.

Single-point Calibration

Steps for calibrating the meter with a single buffer solution.

Two-point Calibration

Procedure for calibrating the meter with two buffer solutions for higher accuracy.

Exit Calibration and Reset Defaults

How to exit calibration mode or reset settings to factory defaults.

Electrode Condition

Explanation of the indicator for the probe's operational status.

Sensor Check

Method to test the electrode's performance and offset/slope values.

ORP Measurement

Instructions for taking Oxidation-Reduction Potential (ORP) readings.

Meter Setup

Setup Mode

Accessing and navigating the meter's configuration menu.

Battery Replacement

Accessories

Electrode Maintenance

Preparation

Steps to get the electrode ready for use, including rinsing and soaking.

Storage

Guidelines for keeping the electrode moist and protected when not in use.

Certification

Recommendations for Users

Warranty