EasyManua.ls Logo

Hardi MEGA 230 - Maintenance of Triplets

Hardi MEGA 230
90 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
55
HARDI MEGA 230 / 350 CENTRIFUGAL OPERATORS MANUAL
7.8 Maintenance of Triplets (When Fitted)
Every 40 hours the triplets should be disassembled removed and
cleaned. This is done by pulling out the stainless clip on the side of the
triplet assembly.
Clean the bottom part as well as the top part throughly.
Coat o-ring surface with a light film of vegetable oil, if unit is to be stored
for a long period of time.
If the triplets are not cleaned regularly they may become hard to turn,
with possible damage to them as a result.
WARNING:NEVER SERVICE YOUR CONTAMINATED NOZZLES
WITHOUT WEARING CHEMICAL RESISTANT GLOVES AND
SAFETY GOGGLES.
Fig. 35