43
dB steps.
4- Adjustment 2: This area contains a set of four tabs with different sets of options for more advanced
microphone adjustments.
Equalizer: The equalizer is a 3-band parametric equalizer enabling you to set 3 frequencies to any value
from 20Hz to 20KHz. The default center frequencies are 500Hz, 1000Hz, and 3000Hz. Each band is set
individually by selecting the band from the Band menu then adjusting the remaining settings. A dynamics
chart displays any activity on the equalizer band. Changing the Gain, Frequency, or Q settings can change
the chart display.
Use the following options to change the settings on the equalizer:
Band: Use the menu to select which of the 3 equalizer bands you want to configure.
Filter Type: Use the menu to set the filter type for the selected equalizer band. You can choose from Bell,
Band Pass, Band Stop, High Pass, Low Pass, Treble Shelf, and Bass Shelf.
Frequency: Use the up and down arrows or direct text entry to set the center frequency for the selected
equalizer band. You
can set the center frequency to any value between 20Hz and 20KHz.
Gain: Use the up and down arrow buttons or direct text entry to adjust the gain/attention level of the audio
input. You can set the gain from -12 to +12dB in 1dB increments. The default setting is 0.
Q: Q factor adjusts the vector graph from wider to narrower smoothing between inflection points on the
equalizer band. The default setting is 1.4. The range is from 0.1 to 20.0 in 0.1 increment/decrement steps.
Gating: Use the menu to select the gating level of the selected microphone input. You can choose from Off,
Low, Medium, High, and Custom. The default value is Off. Selecting any option other than Off enables you
to adjust settings for Attack, Release, Depth, Hold Off, and Threshold.
Limiter: Use the menu to select the Limiter settings of the selected microphone input. You can choose from
Off, Low, Medium, High, and Custom. The default value is Off. Selecting any option other than Off enables
you to adjust settings for Attack, Release and Threshold.
Compression: Use the menu to select the compression level of the selected Microphone input. You can
choose from Off, Low, Medium, High, and Custom. The default value is Off. Selecting any option other than
Off enables you to adjust settings for Attack, Release, Ratio, and Threshold.
The following settings serve identical purposes with identical ranges for each tab on which they appear:
Attack: Sets the duration, in milliseconds, of the attack phase. You can set a value between 1 and 2000.
Release: Sets the duration, in milliseconds, of the release phase. You can set a value between 1 and 5000.
Depth: Sets the depth in decibels. You can set a value between 0 and 20.
Ratio: Sets the ratio. You can set a value between 1 and 20.
Hold Off: Sets the gating hold off time. You can set a value between 0.25 and 4 seconds in 0.25 increments.
Enabled: Click to enable or disable the equalizer settings.