10
Super-Magnum Coal Stoker Stove
Do Not Burn Wet Coal! 3-90-02702R8_11/13
B. Clearances To Combustibles
A C
D
B
F
E
E
C
D
B
A
Parallel
Installation
Inches Millimeters
BackWallToUnitHopper
SideWallToUnit
BackWallToFlueConnector
SideWallToFlueConnector
251
17432
24610
34864
F
E
Corner
Installation
Inches Millimeters
WallstoUnitBody
WallstoFlueConnector
15381
24610
C. Floor Protection Requirements
Floorprotectionmustbeof a non-combustible material.It
must be located under the appliance and extend beyond
theapplianceaccordingtothemeasurementsbelow.Floor
protectionmustalsoextendunderanyhorizontalsections
ofchimneyconnectorand2"(50.8mm)beyondeachsideof
the connector.
DANGER: The appliance legs may not be removed for
installation.
MinimumSizeoorprotectionis49½"DeepBy42¾"Wide.
J
G
Floor Protection
Requirements
Inches Millimeters
Sides-USA/CANADA*
Rear-USA
8203
12305
H Front-USA/CANADA*
18457
GG
H
J
54"
54"
Alternate oor protector dimension may be used as long
as they satisfy the measurement requirements shown
above.
Minumum size oor protection for a corner installation
hearth pad is 54" x 54" (USA ONLY).