24
Super-Magnum Coal Stoker Stove
Do Not Burn Wet Coal! 3-90-02702R8_11/13
Whenproperlymaintained,yourstovewillgiveyoumany
yearsoftrouble-freeservice.Contactyourdealertoanswer
questionsregardingproperoperation,trouble-shootingand
serviceforyourappliance.Visitwww.harmanstove.comto
ndadealer.Werecommendannualservicebyaqualied
service technician.
A. Shut-down Procedure
Thebestwaytoshutdowntheapplianceistosimplyletit
runoutoffuel,andshutdownnaturallyasthetemperature
cools.Thismethodishighlyrecommendedfortheendof
seasonshut-down.
To shut-down otherwise, turn the mode selector to "OFF'
verifybyensuringthattheStatuslightgoesout.Theshut-
downprotocolofthecircuitboardwillsafelyallowthere
to go out.
B. Quick Reference Maintenance Chart
Cleaning or Inspection Frequency Daily Weekly Monthly Yearly
Areabeneathregrates Aftereachtonburned OR X
Ashremoval Wheneverllingtheunithopper OR X
Combustionblower
Morefrequentlydependingon
surroundings OR X
Distributionairlter Replaceasneeded OR X
Distributionblower
Morefrequentlydependingon
surroundings OR X
Doorlatchinspection Priortoheatingseason OR X
Finestray Dependingonfuelquality OR X
Firebox/thoroughcleaning Endofheatingseason OR X
Glass
Whenveiwofrebecomes
obstructed OR X
Heatexchanger/Chainscraper Wheneverllingtheunithopper OR X
Hopper Wheneveraddingfuel OR X
Ventingsystem
Morefrequentlydependingonfuel
quality and quantity OR X
Soot Formation and Need For Removal- When coal is
burned,theproductsofcombustioncombinewithmoisture
toformasootresiduewhichaccumulatesontheuelining.
When ignited, this soot makes an extremely hot re. The
chimney and chimney connector should be inspected at
least once every two months during the heating season
to determine if a soot buildup has occurred. If soot has
accumulated,itshouldberemovedtoreducetheriskofa
chimneyre.
Removeallburningfuel
fromthegratebyscrapingitintotheashpan.Movetheash
pan safely outside the home and place it on the ground,
wellawayfromanycombustibles.Turnthecontrolto"Off"
andnotifytheredepartment.Donotoperatetheappliance
untilthechimneyandconnectorhavebeeninspectedand
approvedbyachimneyprofessional.
10