15
Do Not Burn Wet Coal!
Super-Magnum Coal Stoker Stove
3-90-02702R8_11/13
6
Mobile Home
A. Mobile Home Installation
Mobile home approval - U.S. only.
1. An outside air inlet must be provided for combustion
air,andmustremainclearofleaves,debris,ice,and/or
snow.Theoutsideairpathmustbeunrestrictedwhilethe
appliance is in operation.
2. The combustion air intake system must be of metal
construction.Itmustpermitzero-clearancetocombustible
materials,andcontainarodentscreen.
3. The appliance must be secured to the mobile home
structure by bolting it to the oor. There are brackets
included,you'llneedtosecurewiththeproperlengthlag
bolts.
4. Theappliancemustbegroundedtothemetalframingof
themobilehome
5. All clearances to combustibles and oor protection
requirementsmustbefollowed.
6. Follow the vent manufacturer's instructions when
installinginamobilehome.
7. InstallationshallbeinaccordancewiththeManufactured
HomeandSafetyStandard(HUD)CFR3280,Part24
8. The appliance must never be installed in a room
designated for sleeping.
Thisdiagramshowsthebracketthatwasusedtoboltthe
stoveto the pallet. Use atleast two of these bracketsfor
securingtheappliancethroughtheoorinamobilehome
installation.Thebracketwillslipoverthetopoftheleveling
adjuster.Theinstallerwillneedtodetermineandobtainthe
properlysizedlagbolts.
Installation must comply with Manufactured Home and
SafetyStandard(HUD),CFR3280,Part24.
Never install in a room intended for sleeping.
Maintain structural integrity of mobile home:
 Floor, wall, ceiling and/or roof.
DoNOTcutthrough:
• Floorjoist,wallstuds,orceilingtrusses.
• Any supporting material that would affect the
structural integrity.
Neverdrawoutsidecombustionairfrom:
• Wall,oororceilingcavity.
• Enclosedspacesuchasanatticorgarage
CAUTION
!