a. Feed Rate Adjustment
TheCircuitboardrunsonaoneminutetimercycle.Each
minute,theboardisthinkingaheadtowhatitneedstodo
for the next minute to maintain or achieve the demanded
temperature.Whatyouaresettingonthefeedadjusterdial
isthemaximumamountoffeedtime,perminute,thatyou'll
allow.Thecircuitboardwillmakeitsowndeterminationof
how long to run the feeder, UP TO the maximum as set
on the dial. For instance, a number 4 settingon the feed
adjusterwillallowamaximumof40secondsperminuteof
feed.Iftheroomtemperatureissatised,withonlyfeeding
20 seconds, then that is all the circuit board will run the
feeder. In most tested scenarios, the number 4 setting is
adequate, however, fuel quality may dictate a higher or
lower setting. If you see un-burned or burning coal being
pushedoffofthe grate during ahigh demand period, the
feed rate is set too high. Ideally, you'll want to see about
aninchofashesinfrontoftheburningcoalduringapeak
demandperiod.Settingthefeedratetoolowmaynotallow
thedemandtemperaturetobemet.Keepingthesettingat
#4 or above will work with most batches of coal.Allow a
minimumofonehourbetweenadjustments.
Note: Since the circuit board is feeding as needed, 
only adjust the feed rate while maximum demand is 
occurring. (Stove Temp Mode, with a temp dial setting 
of #7 will create maximum demand.)
b. Mode Selection
Room-Temp mode is the ideal mode of operation if you
wish to maintain a comfortable temperature in the  room.
Astheoutdoortemperatureuctuates,theSuperMagnum
willadjustthefeedratetomaintainthedesiredtemperature
settingintheroom.Forbestresults,besuretheroomsensor
is located outside of any drafty areas and not positioned on 
theoorornearanexteriorwall.
Stove-Tempmodeismoreofamanualmethodofoperation.
Thestovewillrunataconstantheatoutput,regardlessof
outsideairtemperature.Notethatonthecoldestdays,your
indoor heated space will be cooler than on the warmer
days.Theonlyrealbenettothismodeofoperationisthat
you'llbeabletoknowexactlyhowlongahopperfullofcoal
willlast,becausetheconsumptionisgoingtostayrelatively
thesame.
c. Temperature Dial
Thetemperaturedialisadualpurposedial.InRoom-Temp
mode,youselecttheroomtemperatureyouwantthestove
to maintain at the room sensor probe. This is marked in
fahrenheit scale from 50 to 90 degrees. In Stove-Temp
mode,youselectatemperaturesettingbasedonthe#1-7
with1beingaminimumburnand7beingamaximumburn
rate.
d. Blower Speed Adjustment
ThemodeselectorisalsomarkedwithaLtoHscale,ineach
mode.Thisisa variable speedcontrol for the distribution
blower. L  is the low setting, and H is the high setting. It
isimportanttonotethattheblowerwillnotcomeonuntil
theESPreachesahighenoughtemperaturetoensurethat
coldairisnotbeingblownoutintotheroom.Also,thespeed
oftheblower,whensetonlowerspeeds,willautomatically
increaseasthetemperatureofthestoveincreases.
        
closed while in operation. Maintain all door seals and 
gaskets in good condition. Replace gaskets when 
necessary using parts obtianed through your Harman® 
dealer.