Hartzell CD15K - 9.3.8 INSPECTION OF REMAINING COMPONENTS; 9.3.8.1 Always replace all grommets, gaskets, O-rings and rubber parts at overhaul.; 9.3.8.2 Inspect all wiring for chafed, cracked or damaged insulation. Replace if necessary with MIL-W-22759;18 AWG wire, cut to length and crimping on terminal ends.; 9.3.8.3 Reinstall heater controls if they were operating correctly before overhaul.

Hartzell CD15K
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2900 Selma Highway, Montgomery AL 36108 USA
PH: +1.334.386.5400 (option 2) FAX: +1.334.386.5450 WEB: www.hartzell.aero
Page | 31
MM10001
Dated 1/1/08
Rev L dated 5/21/15
9.3.8 INSPECTION OF REMAINING COMPONENTS
9.3.8.1 Always replace all grommets, gaskets, O-rings and rubber parts at overhaul.
9.3.8.2 Inspect all wiring for chafed, cracked or damaged insulation. Replace if
necessary with MIL-W-22759/18 AWG wire, cut to length and crimping on
terminal ends.
NOTE: If cracks or distortions are evident on the terminal strip, it must be replaced.
NOTE: Do not use solder for heater wiring connections.
9.3.8.3 Reinstall heater controls if they were operating correctly before overhaul.
9.3.8.4 Replace all damaged hardware.