11
For two speed pumps, this setting will be the period of time when the pump runs at high
speed (the word “Filter T1” in the display will be replaced with “Filter Hi”). There is a
separate timeclock for the low speed operation (see “Filter T2” below). If the high speed and
low speed periods overlap, then the pump will operate in low speed during the overlap
period.
There are several reasons the filter pump may be running at times other than the timeclock
period set above. These include super-chlorination, spa operation, manual operation, heater
cooldown, freeze protection and “solar-extend”.
For one speed pumps, this is the second filter timeclock
For two speed pumps, this timeclock will set the normal time period for filter pump low speed
operation (the word “Filter T2” in the display will be replaced with “Filter Lo”). If the filter
pump was off prior to the start of this time period, the filter pump will first turn on at high
speed for 3 minutes to prime and establish water flow. Afterwards, it will drop down to low
speed for the remainder of the programmed low speed time period. While this time clock will
override the high speed timeclock (see above), there are several reasons why the pump will
automatically switch to high speed operation during this programmed time period. These
include manual operation, spa operation, or heating operation. Refer to page 10 for general
notes regarding timeclock programming.
This menu is only available if the system has been setup for “spa only” or “pool and spa”.
During the programmed spa time, the Aqua Logic will turn on the filter pump and move the
pool/spa valves into the “spa-only” position. The heater will automatically heat the spa up
to the programmed spa temperature (page 7). This programmed spa operation will take
precedence over all other automatic functions, only manual operation of the filter button or
pool/spa valve button will override this function.
If your pool has a separate jet pump or blower controlled by Aux1 and/or Aux2 , you will have
to program those separately (see page 12).
Set Day and Time
Wednesday 10:37P
+
>
>
Adjust time setting
Move between start and stop times & to previous/next menu item
Spa-all
6:00P to 9:00P
+
>
>
Adjust time s
Spa-wkend
6:00P to 9:00P
Spa-wkday
6:00P to 9:00P
+
+
>
>
>
>
Adjust time setting
Adjust time setting
Move between start and stop times & to previous/next menu item
Move between start and stop times & to previous/next menu item
or
Set Day and Time
Wednesday 10:37P
+
>
>
Adjust time setting
Move between start and stop times & to previous/next menu item
Filter T2-all
8:30A to 4:00P
+
>
>
Adjust time s
Filter T2-wkend
8:30A to 4:00P
Filter T2-wkday
8:30A to 4:00P
+
+
>
>
>
>
Adjust time setting
Adjust time setting
Move between start and stop times & to previous/next menu item
Move between start and stop times & to previous/next menu item
or