Keep your EDB-2 H.E and signal cables away
from devices with strong magnetic fields, or
mobile/cellular phones. These include large AC
mains transformers, generators, lighting control
systems and non earthed fluorescent lighting
Switch off equipment which is causing
interference. Keep signal cables away from mains
and speaker leads
Check mains power leads are not coiled
Use highly screened microphone or instrument
leads, with metal shielded connectors and good
connections
Shorten or uncoil cable runs
When using the XLR to Jack adaptor for a D.I.
output, set the Earth/GND LIFT switch to cut earth
loop hums if required. Otherwise leave Earth Lift
switch Off
Use "Notch Filter" with narrow "Q" to hone in on
troublesome hum and cut it (at around 50-60Hz) or
cut fluorescent light buzz (at around 100-130 Hz)
Mains Filters prevent noise transmitting through
mains power which can affect amplifiers
If lighting is causing hum and/or buzz, power your
amplifier from a different AC mains ring that is not
being used for stage facilities or lighting
Hum and buzz can be generated in a stringed
instrument where there is no earth connection
between output jack, strings or any tail piece