DualBrite
®
Replacement
Sensor Head
Features
• Turnsonlightingwhenmotionisdetected.
• Automaticallyturnslightingoff.
• PatentedDualBrite
®
Timer.
• Photocellkeepsthelightingoffduringdaylighthours.
• LEDindicatesmotionwassensed(dayornight).
Requirements
• Notforusewithuorescentlights.
• Thelightcontrolrequires120-voltsAC.
• IfyouwanttouseManualMode,thecontrolmustbe
wiredthroughaswitch.
• Install sensor in accordance with local codes.
©2012HeathCoLLC 204027-01A
Model5316
OPERATION
*resetstoAutoModeatdawn.
Note:Whenrstturnedonwaitabout1
1
/
2
minutesfor
thecircuitrytocalibrate.
TEST
TEST 1520
ON-TIME
Off 3 6 Duskto
Dawn
DualBrite
®
PutON-TIMEswitchon
the sensor bottom to
TESTandtheDualBrite
®
switchOFF.
DualBrite
®
TIMER
Lightcomesonhalfbrightforselectedtimeafterdusk
(Off,3hr.,6hr.,untildawn).SelectingOFFdisablesthis
feature.Themotionsensingfeatureswillcontinuetowork
asdescribedinthismanual.Ifmotionissensed,thelight
turnsonfullbrightfortheON-TIME(1,5,or20minutes)
thenreturnstodimmode.
MANUAL MODE
ON-TIME
TEST 1 5 20
AUTO
Move ON-TIME Switch to 1,
5, or 20 minutes
Mode Switching Summary
Flip light switch off
for one second then
back on*
MANUAL MODE
AUTO
TEST
* Ifyougetconfusedwhileswitchingmodes,turnthepower
offforoneminute,thenbackon.Afterthecalibration
timethecontrolwillbeintheAUTOmode.
Manualmodeonlyworksatnightbe-
cause daylight returns the sensor to
AUTO.
Flipthelightswitchoffforonesecond
thenbackontotogglebetweenAUTO
andMANUALMODE.
ManualmodeworksonlywiththeON-
TIMEswitchinthe1,5,or20position.
PuttheON-TIMEswitchinthe1,5,
or20minuteposition.
...backon.
1Second
OFFthen...
Mode: On-Time: Works: Day Night
Test
5Seconds x x
Normal
1,5,20min. x
Manual
UntilDawn* x

Questions and Answers:

Heath Zenith 5316 Specifications

General IconGeneral
BrandHeath Zenith
Model5316
CategoryAccessories
LanguageEnglish

Summary

Product Features and Requirements

Key Features

Highlights include automatic lighting, DUALBRITE® timer, photocell, and motion detection LED.

Operational Requirements

Specifies compatibility with 120-volt AC, exclusion of fluorescent lights, and wiring for Manual Mode.

Operating Modes Overview

Explains the TEST, AUTO, and MANUAL modes and the DUALBRITE® timer functionality.

Installation and Mounting Guide

Eave Mount Installation

Provides specific steps for rotating the sensor head when mounting on eaves.

Wiring the Light Control

Details the process of connecting sensor wires to the light control using wire connectors.

Mounting the Light Fixture

Instructions on physically attaching and adjusting the light fixture and sensor.

Testing and Adjustment Procedures

Sensor Aiming and Coverage Adjustment

Guides on adjusting the sensor's aim for optimal coverage and avoiding false triggers.

Range and Angle Specifications

Details the maximum sensing range and coverage angle of the motion sensor.

Setting Controls and Specifications

Instructions for setting ON-TIME, DUALBRITE® timer, and summary of product specifications.

Troubleshooting and Support

Troubleshooting Common Issues

Addresses various symptoms like lights not turning on, staying on, or flashing unexpectedly.

Technical Service and Warranty Information

Provides contact details for technical support and outlines the two-year limited warranty.

Related product manuals