Page #40 background imageLoading...
Page #40 background image
GRAY
INSULATING
PAPER
4-40
x
112"
SELF-TAPPING
SCREW
SOFT
CLOTH
FRONT
PANEL
MOUNTING
Refer to
Pictorial
25
for
the
following steps'
Refer to
Detail 25A
for the
following
three
steps.
t.n"oo
@
()
()
()
DOUBLE
ADHESIVE
(
)
Carefully
bend
the
two solder
lugs on
the meter
so
they
point
straight
out
from the
meter
body
as shoWn.
(
)
Refer to
Detail 25C
and cut
a
piece
of white
vinyl
gasket
2"
long by
112"
wide
from
one of the
two
pieces
furnished.
Save
the
indicated
portion
of the
oasket
for use
later.
Place the
front
panel
face down
on
a soft
cloth
on
your
workbench
so
the hollow
bosses
at
T
and
R are
facing upward.
Tap
threads
in
each
of the
two bosses
by
turning
the
4-40 x 112"
self'tapping
screw
into
each boss
until
there
is
just
1/8"
between
the
underside
of the screw
head
and
the
end of
the
boss.
Use
force
on the screwdriver,
turn
slowly,
and
do
not
permit
the screw
to
lean
in any
direction.
Remove
the
screw
and
save
it
for use
later.
Cut
a
piece
of
gray
insulating
paper
1"
x
2-314".
Discard
the
remaining
paper.
Remove
the white
protective
covering
from
the
gray
paper,
and
press
the
adhesive
side
of
the
gray
paper
onto
the back
of
the
front
panel
in
the
position
shown.
Be
careful
not to
cover
any
part
of
the
panel
holes.
3;tii
DISCARD
THIS
PIICE
U5I
THIS
PIECE
rl
Detail2SC
Refer
to
Detail 25D
for
the next
two
steps.
(
)
Remove
the
protective covering
from
one
side
only
of
the 2"
x 1
12"
vinvl
gasket
cut
in the
preceding
step'
(
)
Refer
to
Detail 258.
remove
the
protective
coating
from
one side
only of
the
1" length
of double-adhesive
tape
laid aside
earlier,
and
press
this
side
against
the
front
of the
meter
just
below
the
projection for
the
meter
scale.
NOTE:
In the
following step,
be sure
the
meter scale
is
right
side
up before
permitting
the
adhesive
tape
to touch
the
back
of the
panel.
(
)
Remove the
protective
coating
from
the
front
of the
tape
on
the meter.
Then,
from
the back
of
the
panel
place
the
meter scale
projection into
the rectangular
opening
at Z on
the
front
panel.
Press the
meter
firmly
into
place.
(
)
Position
the adhesive
side
of
the
gasket
on
the
painted
side
of
the subpanel
so
the
strip
is
exactly
centered
over
the square
meter
hole
and
one
end is 1/8"
above
the
offset,
or step,
of
the subpanel.
Rub
the
gasket
material
firmlY into
Place.
(
)
Carefully
remove
the
protective
covering
from
the
upper
side
of the
gasket.
CAUTION:
As
you
mount
the
front
panel in the
following
step,
make
sure
it is
properly
aligned
with
the
subpanel
so
the back
of
the
meter
will
be
aligned
with
the
meter
mounting
hole
in the
subpanel
before
the
meter
touches the
vinyl
gasket.
See
Pictorial 25.
I