Take the wall template and place in the desired position
on the wall, giving due consideration to the required boiler
clearances, see chapter "Appliance location ► Clearances",
and the  ue you are  tting.
Fixing to the wall
130
90°
4
5
6
2
1
3
Key
1 Wall template
2 Standard  ue length horizontal
3 2.5° 44mm/metre inclined extended  ue length
4 Wall plug
5 Hanging bracket
6 Screw
Flue hole cutting
Mark the position of the  ue centre.
Remove the wall template, then drilling the  ue hole.
The fl ue is designed with an internal fall of 44mm/
metre (2.5
o
), therefore the hole can be drilled
horizontally.
Use a 105mm diameter core drill for external access  ue
installation (60/100  ue).
Use a 125mm diameter core drill for internal access only  ue
installation (60/100  ue).
If fl ue extension pipes are to be used then a core
drill size of 125mm is required. This will allow the
extension pieces to slope at 44mm/metre (2.5
o
)
towards the boiler.
If  tting a side  ue, extend the  ue centre line into the corner
then 130mm along the adjacent wall.
If  tting an extended side  ue, determine the  ue hole centre
by extending the dashed inclined line on the template to the
side wall. This dashed line is drawn at 44mm/metre (2.5
o
)
rise from the boiler. Where this line reaches the side wall, a
horizontal line should be marked. The vertical centre line of
the  ue should then be marked at 130mm from the back wall.
To allow for the  ue passing through the wall at this angle
a 125mm hole should be drilled irrespective of internal or
external installation.
Hanging bracket fi xing
Due to the varied site conditions the  xings supplied may not be
suitable, please make sure that those used are.
Drill the holes for the  xing screws in accordance with the wall
template.
Fix the hanging bracket on the wall.