6.1.7 Machine parameters for other functions
Function
Parameter Possible
NO.
entry values
Selected
entry values
Resolution
With parameter 65 the resolution of TNC 15l/TNC 155 can be programmed for either 1 urn or 5 pm.
For optimization of machine parameters, 1 urn is used. The 5 pm resolution is usually sufficient for normal
machine operation.
Signal evaluation
X
12
A
1 -
20-fold max. traversing
Y 13
speed 16 [m/min]
Z
14
2 4
=
1 O-fold max. traversing
IV 15
speed 12 [m/min]
With these parameters, the signal evaluation for the transducers can be reduced from 20-fold to 1 O-fold.
Please note:
With IO-fold subdivision the max. traversing speed is 12 m/min (input frequency of control 20 kHz).
Standstill supervision
169
0,001 . 30 [mm]
-i------
Parameter 169 determines the range in which non-controlled axes may move without activition of a fault
detection signal. If the programmed limitation is exceeded, the control then goes into an emergency stop
condition and indicates the flashing message GROSS POSITIONING ERROR.
T
--
Movement supervision
234
T
0.03.. 10 Cvl
Parameter 234 monitors machine movement when the programmed voltage is output. If no movement
takes place, the control goes into the emergency stop condition and indicates the flashing message
GROSS POSITIONING ERROR.
.-
Off-line programming station
170 0 h
=
Control
/\
1 -
Off-line programming
station PLC active
2 A
=
Off-line programming
station PLC inactive
Parameter 170 determines whether the control is intended as an off-line programming station or not. If
parameter 170 is programmed with 1 or 2, the control requires no transducers or external circuitry.
Cancellation of status display
173 0 A
=
Status display is not
with M02, M30 and program
to be cancelled
end
2
1 -
Status display is to
be cancel led
Program conditions are indicated in the status display of the TNC 151/TNC 155. These status data are required
for re-entry into an amended contour after an operational interruption. If these program status data are to be
cancelled at the end of the program, MP173 should be programmed with “1”.
49