13 Tables and Overviews
328
13.1 General User Parameters
Display step for the 6th axis
MP7290.5
For input values, see MP7290.0
Display step for the 7th axis
MP7290.6
For input values, see MP7290.0
Display step for the 8th axis
MP7290.7
For input values, see MP7290.0
Display step for the 9th axis
MP7290.8
For input values, see MP7290.0
Disable datum setting
MP7295
Do not disable datum setting: +0
Disable datum setting in the X axis: +1
Disable datum setting in the Y axis: +2
Disable datum setting in the Z axis: +4
Disable datum setting in the IV axis: +8
Disable datum setting in the V axis: +16
Disable datum setting in the 6th axis: +32
Disable datum setting in the 7th axis: +64
Disable datum setting in the 8th axis: +128
Disable datum setting in the 9th axis: +256
Disable datum setting with the orange axis keys
MP7296
Do not inhibit datum setting: 0
Disable datum setting with the orange axis keys: 1
Reset status display, Q parameters and tool data
MP7300
Reset them all when a program is selected: 0
Reset them all when a program is selected and with
M02, M30, END PGM: 1
Reset only status display and tool data when a program is selected: 2
Reset only status display and tool data when a program is selected and
with M02, M30, END PGM: 3
Reset status display and Q parameters when a program is selected: 4
Reset status display and Q parameters when a program is selected
and with M02, M30, END PGM: 5
Reset status display when a program is selected: 6
Reset status display when a program is selected and with M02, M30,
END PGM: 7
Pkap13.pm6 30.06.2006, 07:04328