HEIDENHAIN Programming Station TNC 320/TNC 620/TNC 640 19
1.2 Compatibility
Differences in touch probe cycles
Touch-probe cycles of the iTNC 530, TNC 426/TNC 430, TNC 310
and TNC 410 controls
Meaning of the symbols used in the table:
Parameter not available in this software version
þ Parameter or cycle available in this software version
x Cycle not available in this software version
Cycle
Additional
parameters
iTNC 530
TNC 426/
TNC 430
TNC 310 TNC 410
340490 280476 286140 286060
0, Reference plane þþx þ
1, Polar datum þþxx
2, Calibrate TS þþxx
3, Measuring MB
REFERENCE
SYSTEM
þ
þ
x
x
4, Measuring in 3-D þ xxx
9, Calibrate TS length þ xxx
400, Basic rotation Q305 þ –xx
401, Rotation of 2 holes Q305
Q402
Q337
þ
þ
þ
x
x
x
x
x
x
402, Rotation of 2 studs Q305
Q402
Q337
þ
þ
þ
x
x
x
x
x
x
403, Rotation in rotary axis Q337
Q305
Q303
Q380
þ
þ
þ
þ
x
x
x
x
x
x
x
x
404, Set basic rotation þ xxx
405, Rotation in C axis þ xxx
408, Slot center reference point þ xxx
409, Ridge center reference point þ xxx