This component is located behind the left control panel and
regulatesvoltagetotheltermotor.
Replacement:
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Hinge-down the left control panel.
2. Label and remove wires from relay.
3. Using a 5/16” wrench, remove the nuts securing the relay
and remove relay from fryer.
4. Install new relay in reverse order.
6-17. FILTER MOTOR RELAY