Model EEE-182
6-26
Replacement:
1. Pull-out on the drain knob and drain oil from vat.
2. Using a 1/2” wrench, remove the nut on the compression
tting,andremovethetemperatureprobefromthevat.
3. Using a terminal extractor, remove the probe terminals from
the connector and pull remove probe from unit.
4. Place the nut and new ferrule on the new temperature probe
and insert the temperature probe into the compression
tting.
Follow probe installation instructions below:
Excess force will damage temperature probe. Hand-tighten
nut and then 1/2 turn with a wrench.
6-20. OIL LEVEL PROBES
(Continued)
July 2016