1.3 Operation and maintenance
1.3.1 General notes
For safe operation and
maintenance of all equipment, it is
assumed that actions will be
carried out appropriately by
qualified staff, taking heed of the
warning notes in this
documentation and the notes on
the equipment.
Under incorrect operating
conditions, temperatures above
80°C could occur at parts of the
casing.
1.3.2 Operation
General safety notes
Coverings that prevent the
moving of hot or rotating parts or
which are required for the correct
supply of air and effective
functioning must not be opened
during operation.
Any faults or unusual operating
conditions such as the emission
of smoke or the appearance of
flames mean that the equipment
must be immediately switched off
using EMERGENCY OFF. The
HERZ factory customer service
must then be notified of this
straight away.
When the main switch at the back of the
boiler is deactivated or if the power supply
fails, the equipment immediately goes out of
operation. The residual amount of fuel burns
independently without toxic gases being
given off, provided that the naturally
occurring chimney draw is sufficiently high.
The chimney must therefore be dimensioned
and designed according to EN 13384. When
resetting the installation it is obligatory to
check for serviceability and to ensure safe
operation of the total installation.
The noise caused by the machinery during
operation does not have any adverse effects
upon the health of people.
1.3.3 Maintenance
General safety measures
Before commencing any work on the equipment,
but particularly before opening coverings of parts
under voltage, the equipment must be enabled
according to the instructions. As well as the main
electrical circuit, any additional or auxiliary circuits
should be noted. The usual safety rules according
to ÖNORM are:
Switch off all poles on all sides
Ensure that they is not switched on again
Check that there is no voltage
Earth and short-circuit
Covering neighbouring live parts and isolate
dangerous parts
The aforementioned measures
may only be retracted once the
equipment is completely installed
and the maintenance completed.
For overhaul work in the
combustion chamber, ash
chamber, on flue gas-carrying
parts, emptying of the ash store,
etc., the use of personal dust
protection masks and gloves is
required.
For overhaul work in the storage
room, low voltage bulbs must be
used. The design of electrical
equipment in the storeroom must
conform to ÖNM7137.
In order to prevent any commissioning errors due
to incorrect maintenance, it is recommended that
regular maintenance servicing be carried out by
authorised staff or the HERZ factory customer
service.
Spare parts may only be obtained direct from the
manufacturer or sales partner. No health risks will
be caused to the customer from noise arising from
the machinery. Details of any residual risks can be
requested from the residual risk analysis from
Herz as required.