Description of the menu navigation and adjustment values
22 Betriebsanleitung_firestar_18-40_Lambda_Englisch_V1.6
9.3 Parameter menu (P)
At this temperature ends the condition CONTROL PHASE(4) (Equipment changes into condition
READY(5))
At this temperature starts the CONTROL PHASE(4)
FLUEGAS NOMINAL LOAD (password protected)
Flue gas-Must-Temperature at nominal load
FLUEGAS PARTIAL LOAD (password protected):
Flue gas-Must-Temperature at partial load
MIN FLUE GAS (password protected):
This parameter determines the minimum flue temperature which is required for leaving the
burning phase.
MAXIMUM RE-START (password protected)
maximal duration of the Re-start
PRIMARY AIR FLAP MIN (password protected):
Minimal primary air flap position
O2 MUST (password protected):
O2 – must value for combustion control
BUFFER DIFFERENCE (password protected)
Difference between boiler temperature and actual buffer-lower-temperature. For the controlling of
the Backflow-pump.
By pressing the button:
The equipment is switched on/off
(S) changes into menu „STATUS“
(A) changes into menu „AGGREGATETEST-OUTPUT“ (if code is active)
The value can be modified